I generate three starting models for the inversion of a set shallow seismic refraction data using wavepath eikonal traveltime tomography. Two models are generated with the generalized reciprocal method (GRM), which uses a multi-layer model with discrete velocity changes while the other is generated with a one dimensional (ID) inversion algorithm similar to the tau-p method, which uses a model with vertical velocity gradients. There is little correlation between the results in either the absolute depths, the relative depths or the refractor velocities.

I attribute the differences in the absolute depths to the occurrence of a velocity reversal in the overburden, the existence of which is indicated by the concave-upwards shape of the traveltime graphs and by the extremely rapid decrease in amplitudes.

I attribute the differences in the relative depths and seismic velocities to the poor starting model generated by the ID tau-p inversion algorithm, which is unable to resolve the fundamental ambiguity between seismic velocity and structure on refracting interfaces. The GRM-derived refractor velocities are compatible with the head coefficients determined with amplitude products.

The existence of velocity gradients is suggested by the convergence of the traveltime graphs with increasing shot-to-detector distance. I attribute this convergence in part to the large variations in signal-to-noise ratios, which affect the accuracy of the traveltime data.

The shot amplitudes decrease rather than increase with distance, which supports the occurrence of distinct interfaces with velocity gradients over relatively small depths. Therefore, while velocity gradients are likely to occur, the results generated with ID tau-p tomography are probably not representative of the subsurface conditions.

The considerable differences between the results generated with the GRM and those obtained with ID tau-p tomography are compelling demonstrations of the non-uniqueness of model-based inversion and of the importance of the selection of the initial model. Accordingly, all methods of model-based inversion of shallow refraction data could usefully include starting models generated with the GRM or the refraction convolution section.

Loading

Article metrics loading...

/content/journals/10.1071/ASEG2003ab123
2003-08-01
2026-01-20
Loading full text...

Full text loading...

References

  1. Cerveny, V., and Ravindra, R., 1971, Theory of seismic head waves: Univ of Toronto Press.
  2. Diebold, J. B., and Stoffa, P. 1., 1981, The traveltime equation, tau-p mapping, and inversion of common midpoint data: Geophysics46, 238-254.
  3. Gibson, B. S., Odegard, M. E., and Sutton, G. H., 1979, Nonlinear least-squares inversion of traveltime data for a linear velocity-depth relationship: Geophysics44, 185-194.
  4. Hatherly, P. J., 1982. A computer method for determining seismic first arrival times: Geophysics47, 1431-1436.
  5. Menke W. 1989. Geophysical Data Analysis: Discrete Inverse Theory. Academic Press, Inc.
  6. Palmer D. 1980. The Generalized Reciprocal Method Of Seismic Refraction Interpretation: Society of Exploration Geophysicists, Tulsa, OK.
  7. Palmer, D, 2001a, Imaging refractors with the convolution section: Geophysics66, 1582-1589.
  8. Palmer, D, 2001b, Resolving refractor ambiguities with amplitudes: Geophysics66, 1590-1593.
  9. Ricker, N., 1953, The form and laws of propagation of seismic wavelets: Geophysics18, 10-40.
  10. Schuster, G. T., and Quintus-Bosz, A., 1993, Wavepath eikonal traveltime inversion: theory: Geophysics58, 1314-1323.
  11. Whiteley, R. J., and Greenhalgh, S. A., 1979, Velocity           Zhang J. and Toksoz M. N. 1998. Nonlinear refraction Geoexploration17, 125-141.
  12. inversion and the shallow seismic refraction method: traveltime tomography: Geophysics63, 1726-1737.
/content/journals/10.1071/ASEG2003ab123
Loading
  • Article Type: Research Article
Keyword(s): amplitudes; GRM; RCS; shallow refraction inversion; tomography
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error