1887
ASEG2012 - 22nd Geophysical Conference
  • ISSN: 2202-0586
  • E-ISSN:

Abstract

Summary

High resolution X-ray micro CT has become a very powerful tool for 3D analysis of core and rock samples. The results can be obtained in a non-destructive way and yields to conclusions for a better understanding of rock structures, mineral composition and fluid flow in the pore space just to name a few.

Tendencies of modellers to analyse rock properties at scales going down to μm and even nm forces the industry to develop appropriate equipment for sub-μ applications. The examples chosen in this paper emphasize the capability of the used X-ray CT systems to fulfil modellers’ requirements and cover different fields of investigation like reservoir rocks, volcanology and palaeontology with resolutions down below 1 μm. The described method enables geo-scientists to receive 3D models of their rock samples at sub-μ scale with extraordinary contrast resolution and opens them not only new possibilities in modelling research but also can speed up all further rock analysis by properly choosing slices for thin sectioning as an example. Furthermore not only palaeontologists will appreciate that they are able to virtually cut their valuable samples for visualization without any physical destruction at all.

Loading

Article metrics loading...

/content/journals/10.1071/ASEG2012ab363
2012-12-01
2026-01-22
Loading full text...

Full text loading...

References

  1. Brockdorf, K. et al., 2008. “Sub-micron CT: visualization of internal structures” in Developments in X-ray Tomography VI, edited by Stuart Stock, Proceedings of SPIE, Vol. 7078.
  2. Brunke, O., Brockdorf, K., Drews, S., Müller, B., Donath, T., Herzen, J., Beckmann, F., 2008. „Comparison between x-ray tube-based and synchrotron radiation-based μCT” in Developments in X-Ray Tomography VI, edited by Stuart R. Stock, Proceedings of SPIE, Vol. 7078.
  3. Withers, P., 2007. “X-ray nanotomography”, Materials Today, 10(12), 26-34.
  4. Kastner, J., Harrer, B., Requena, G., Brunke, O., 2010. “A comparative study of high resolution cone beam X-ray tomography and synchrotron tomography applied to Fe- and Al-alloys”, in NDT & E Int. vol 43, pages 599-605.
/content/journals/10.1071/ASEG2012ab363
Loading
  • Article Type: Research Article
Keyword(s): Core Analysis; Reservoir Rock Analysis; Rock Physics; X-ray CT
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error