1887
Volume 29, Issue 1-2
  • ISSN: 0812-3985
  • E-ISSN: 1834-7533

Abstract

An improved conductivity-depth transform method for interpreting time-domain electromagnetic sounding data is amenable to a wide range of transmitter waveforms, source/receiver configurations, and geoelectrical situations. The method is based on a deconvolution scheme that can take into account an arbitrary transmitted current pulse to estimate the step response of the earth from traditional off-time transient electromagnetic (TEM) measurements. Then a rapid imaging scheme that makes use of a current-filament image of the source is applied to transform step response decay curves into resistivity-versus-depth profiles. No assumptions are made regarding the early-time or late-time behaviour of the measured transients. Because of the absence of this or other constraints, the method allows considerable flexibility in its application to real data. This interpretation technique is also fast enough to permit real-time processing of airborne data.

Some new approximate velocity-conductivity functions associated with horizontal and vertical airborne loop sources are derived from a study of the behaviour of electromagnetic fields diffusing through various quasi-layered models. Furthermore, new software has been successfully applied to several ground and airborne data sets, including a GEOTEM data set from Nevada. Comparison of these results with DIGHEM data, ground TEM data, drill hole logs, and geological control indicates that this improved interpretation method produces results that are more accurate than those generated using a commercial conductivity-depth transform scheme that was applied as part of the original survey.

Loading

Article metrics loading...

/content/journals/10.1071/EG998175
1998-03-01
2026-01-14
Loading full text...

Full text loading...

References

  1. Christensen, N.B., 1995, 1D imaging of central loop transient electromagnetic soundings, J. Env. Eng. Geop. 0, 53–66.
  2. Dickson, G.O., and Boyd, G.W., 1980, Newmont transient electromagnetic system, Austral. Soc. Expl. Geophys. Bull. 11, 47–51.
  3. Eaton, P.A., and Hohmann, G.W., 1987, An evaluation of electromagnetic methods in the presence of geologic noise, Geophysics 52, 1106–1126.
  4. Eaton, P.A., and Hohmann, G.W., 1989, A rapid inversion technique for transient electromagnetic soundings, Phys. Earth Planet. Inter. 53, 384–404.
  5. Farquharson, C.G., and Oldenburg, D.W., 1993, Inversion of time-domain electromagnetic data for a horizontally layered earth, Geophys. J. Intenat. 114, 433–442.
  6. Fletcher, R., and Jackson, M.P., 1974, Minimization of a quadratic function of many variables subject only to lower and upper bounds, J. Inst. Math. Appl. 14, 159–174.
  7. Liu, G., and Asten, M., 1993, Conductance-depth imaging of airborne TEM data, Expl. Geophys. 24, 655–662.
  8. Macnae, J., and Lamontagne, Y., 1987, Imaging quasi-layered conductivity structures by simple processing of transient electromagnetic data, Geophysics 52, 545–554.
  9. Macnae, J.C., Smith, R., Polzer, B.D., Lamontagne, Y., and Klinkert, PS., 1991, Conductivity-depth imaging of airborne electromagnetic step-response data, Geophysics 56, 102–114.
  10. Nekut, A.G., 1987, Direct inversion of time-domain electromagnetic data, Geophysics 52, 1431–1435.
  11. Smith, R.S., Annan, A.P., Lemieux, J., and Pedersen, R.N., 1996, Application of a modified GEOTEM system to reconnaissance exploration for kimberlites in the Point Lake area, NWT, Canada, Geophysics 61, 82–92.
  12. Wolfgram, P., and Karlik, G., 1995, Conductivity-depth transform of GEOTEM data, Expl. Geophys. 26, 179–185.
  13. Xiong, Z., 1992, Electromagnetic modeling of 3-D structures by the method of system iteration using integral equations, Geophysics 57, 1556–1561.
/content/journals/10.1071/EG998175
Loading
  • Article Type: Research Article

Most Cited This Month Most Cited RSS feed

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error