Abstract

A

Since the early years of seismic surveying, field engineers and observers have been faced with the appearance of interference at power‐line frequency (and harmonics) on seismic records: 60 Hz in the Americas, 50 Hz in Eurasia; and 16 2/3 Hz (the train supply frequency in Germany, Austria, and Switzerland) in part of Europe. Such interference is picked up from the ground surface through electric leakage between geophone leads and ground.

To minimize power‐line interference, the autobalancer automatically performs a balancing procedure by adjusting two potentiometers on each channel—essentially the same operation as manually performed by seismic operators for decades. The first 24‐channel system became operational in 1977.

The first‐generation design comprised two 256‐position electronic switching potentiometers. Over 4 years of experience with this system in all parts of the world has shown its value under a variety of field conditions. Improvements up to 30 dB were often found, sometimes even up to 40 dB. Balancing time was about 30 s.

A second‐generation design was field‐tested in 1981. Potentiometer stepping is now performed at three levels: coarse, medium, and fine. This leads to faster operation and better resolution: balancing time is about 10 s; improvements up to 60 dB are occasionally found.

A later modification gives a further reduction of the balancing time to 5 s in 60 Hz areas or 6 s in 50 Hz areas.

Loading

Article metrics loading...

/content/journals/10.1111/j.1365-2478.1983.tb01074.x
2006-04-27
2024-04-24
Loading full text...

Full text loading...

References

  1. Adby, P. R. and Dempster, M. A. H.1974, Introduction to Optimization Methods, Chapman & Hall, London .
    [Google Scholar]
  2. Anstey, N. A.1970, Seismic Prospecting Instruments, Volume 1: Signal Characteristics and Instrument Specifications, Gebrüder Borntraeger, Berlin , Stuttgart .
    [Google Scholar]
  3. Evenden, B. S. and Stone, D. R.1971, Seismic Prospecting Instruments, Volume 2: Instrument Performance and Testing, Gebrüder Borntraeger, Berlin , Stuttgart .
    [Google Scholar]
  4. Weber, W.1971, Adaptive Regelungssysteme II: Entscheidungsprozesse und Anwendungsbei‐spiele, R. Oldenbourg Verlag, München‐Wien .
    [Google Scholar]
http://instance.metastore.ingenta.com/content/journals/10.1111/j.1365-2478.1983.tb01074.x
Loading
  • Article Type: Research Article

Most Cited This Month Most Cited RSS feed

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error