1887

Abstract

Summary

The complementary irrigation in the Pampean Region of Argentina may result in a deterioration of soil properties, such as sodification and salinization. It is important then to evaluate soil water content to decide the sheet of water to be applied. The aim was to study the distribution of electrical conductivity (EC) and water content, using electromagnetic soundings to evaluate the effect of irrigation on the soil. Two areas of a lot with corn were studied: one which had been irrigated since 2011 (1) and another one without irrigation (2). Volumetric water content (VWC) was measured with TDR (Time domain reflectometry) in transects along the areas. The geostatistical variograms were estimated for ECa and VWC. The range of correlation of ECa for Area 1 is approximately 8–9 m, while for Area 2 is almost 12 m. The TDR variograms showed pure nugget effect except for two transects with a range of 5 m and 7 m. The periodicity in the series of moving average of ECa and VWC is very similar at the first part of the transects. The TDR measurements of volumetric water content followed the trend of conductivity being the variability greater in the area without irrigation.

Loading

Article metrics loading...

/content/papers/10.3997/2214-4609.201802465
2018-09-09
2024-04-18
Loading full text...

Full text loading...

References

  1. Andriulo, A; Ml.Galetto; CFerreira; GCordone; CSasal
    . [1998]. Efecto de 11 Años de riego complementario sobre un Argiudol típico Pampeano. Ciencia del Suelo, 16(2), 125–127.
    [Google Scholar]
  2. DoolittleJ. A., BrevikE. C.
    [2014] The use of electromagnetic induction techniques in soils studies. Geoderma, 223–225: 33–45
    [Google Scholar]
  3. Eigenberg RogerA., Scott M.Lesch, BryanWoodbury and John A.Nienaber
    . [2008]. Geospatial Methods for Monitoring a Vegetative Treatment Area Receiving Beef Feedlot Runoff. J Environ Qual, 37, S-68–S-77
    [Google Scholar]
  4. Génova, L.
    [2006]. Sustentabilidad de agroecosistemas bajo riego complementario en la Pampa Húmeda Argentina. Cuadernos de Agroecologia, 1(1).
    [Google Scholar]
  5. GénovaL. J.
    [2011]. Calidad del agua subterránea para riego complementario en la Pampa Húmeda argentina. Revista de la Facultad de Agronomía, La Plata, Bs As. Province, 110(2), 63–81
    [Google Scholar]
  6. HuangH.
    [2005]. Depth of investigation for small broadband electromagnetic sensors. Geophysics, 70(6), G135–G142.
    [Google Scholar]
  7. RemyN., BoucherA. WuJ.
    [2009]. Applied geostatistics with SGems. Cambridge University Press. 264 pp
    [Google Scholar]
  8. Vázquez, M. E., Millán, G., & Gelati, P. R.
    [2006]. Efecto del riego complementario sobre la salinidad y sodicidad de diferentes suelos del NO y Centro-E de la provincia de Buenos Aires, Argentina. Revista de la Facultad de Agronomía, 106.
    [Google Scholar]
http://instance.metastore.ingenta.com/content/papers/10.3997/2214-4609.201802465
Loading
/content/papers/10.3997/2214-4609.201802465
Loading

Data & Media loading...

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error