Traditionally, the Poisson-Boltzmann equation is solved to describe the electrical potential in the diffuse layer of an electrolyte adjacent to a charged interface and the electrostatic contribution to the total interaction potential between the interface and the ionic species. A major assumption of the Poisson-Boltzmann equation is that ions act as point charges, which allows for an infinite ion and charge density near to the charged interface, and thus predicts that the zeta potential falls to zero at high ionic strength (typically >0.1M). However, experimental measurements have reported small but measurable zeta potential values at high ionic strength, showing the zeta potential does not tend to zero as predicted.

Electrostatic forces acting between electrically charged mineral-brine and oil-brine interfaces in the classical Derjaguin-Landau-Verwey-Overbeek (DLVO) theory have been used to explain observed increases in oil recovery during low salinity waterflooding. Injection of a low salinity brine is expected to create a more negative zeta potential at the mineral-brine interface. If the oil-brine interface is negatively charged, this increases the electrostatic repulsive force per unit area which, if larger than the disjoining pressure, should lead to improved oil recovery. However, the calculation of the electrostatic forces are normally based on the traditional Poisson-Boltzmann model which underestimates the electrostatic contribution at high salinity.

Here, a modified Poisson-Boltzmann equation ( , Physical Review Letters, 79(3), 435), which accounts for steric effects in the diffuse layer at high salinity but recovers the original Poisson-Boltzmann equation at low salinity, has been combined with a triple layer model which accounts for charge in the Stern layer ( , Journal of Geophysical Research, 104). This combined model has been used to match experimental zeta potential measurements made on natural, intact sandstones across the ionic strength range 10–5 – 5M, including small and constant zeta potentials observed at ionic strength >0.4M. The effect of this modified Poisson-Boltzmann model on the total interaction potential and DLVO theory has further been investigated. Our relatively simple modification shows that the electrostatic forces at high salinity are larger than previously thought and should not be neglected when calculating total interaction forces. Previous models using classic DLVO theory for understanding low salinity waterflooding may be inaccurate as they incorrectly estimate the changes in the electrostatic forces that occur during injection of low salinity brines.

Loading

Article metrics loading...

/content/papers/10.3997/2214-4609.201900072
2019-04-08
2024-04-16
Loading full text...

Full text loading...

References

  1. Al Mahrouqi, D., Vinogradov, J. and Jackson, M. D.
    [2017] Zeta potential of artificial and natural calcite in aqueous solution. Adv Colloid Interface Sci240, 60–76.
    [Google Scholar]
  2. Birdi, K. S.
    [2003] Handbook of surface and colloid chemistry. CRC, Boca Raton, Fla., London.
    [Google Scholar]
  3. Bergström, L.
    [1997] Hamaker constants of inorganic materials. Advances in Colloid and Interface Science70, 125–169.
    [Google Scholar]
  4. Borukhov, I., Andelman, D. and Orland, H.
    [1997] Steric Effects in Electrolytes: A Modified Poisson-Boltzmann Equation. Physical Review Letters79(3), 435–438.
    [Google Scholar]
  5. [2000] Adsorption of large ions from an electrolyte solution: a modified Poisson–Boltzmann equation. Electrochimica Acta46(2–3), 221–229.
    [Google Scholar]
  6. Dawoud, A. M., Jan, V. and D., J. M.
    [2016] Temperature dependence of the zeta potential in intact natural carbonates. Geophysical Research Letters43(22), 11, 578–11, 587.
    [Google Scholar]
  7. Glover, P.
    [2015] Electrical Properties, Treatise Geophys, vol. 189. Elsevier, London.
    [Google Scholar]
  8. Glover, P. W. J.
    [2018] Modelling pH-Dependent and Microstructure-Dependent Streaming Potential Coefficient and Zeta Potential of Porous Sandstones. Transport in Porous Media124(1), 31–56.
    [Google Scholar]
  9. Glover, P. W. J., Walker, E. and Jackson, M. D.
    [2012] Streaming-potential coefficient of reservoir rock: A theoretical model. GEOPHYSICS77(2), D17–D43.
    [Google Scholar]
  10. Hunter, R. J.
    [1981] Zeta potential in colloid science : principles and applications. Academic Press, London.
    [Google Scholar]
  11. Jaafar, M. Z., Vinogradov, J. and Jackson, M. D.
    [2009] Measurement of streaming potential coupling coefficient in sandstones saturated with high salinity NaCl brine. Geophysical Research Letters36(21).
    [Google Scholar]
  12. Jackson, M. D., Al-Mahrouqi, D. and Vinogradov, J.
    [2016a] Zeta potential in oil-water-carbonate systems and its impact on oil recovery during controlled salinity water-flooding. Sci Rep6, 37363.
    [Google Scholar]
  13. Jackson, M. D. and Leinov, E.
    [2012] On the Validity of the “Thin” and “Thick” Double-Layer Assumptions When Calculating Streaming Currents in Porous Media. International Journal of Geophysics2012, 12.
    [Google Scholar]
  14. Jackson, M. D., Vinogradov, J., Hamon, G. and Chamerois, M.
    [2016b] Evidence, mechanisms and improved understanding of controlled salinity waterflooding part 1: Sandstones. Fuel185, 772–793.
    [Google Scholar]
  15. Lager, A., Webb, K. J., Black, C. J. J., Singleton, M. and Sorbie, K. S.
    [2008] Low Salinity Oil Recovery - An Experimental Investigation1.
    [Google Scholar]
  16. Khilar, K. C, Vaidya, R. N. and Fogler, H. S.
    [1990] Colloidally-induced fines release in porous media. Journal of Petroleum Science and Engineering4(3), 213–221.
    [Google Scholar]
  17. Kia, S. F., Fogler, H. S. and Reed, M. G
    [1987] Effect of pH on colloidally induced fines migration. Journal of Colloid and Interface Science118(1), 158–168.
    [Google Scholar]
  18. Li, S., Collini, H. and Jackson, M. D.
    [2018] Anomalous Zeta Potential Trends in Natural Sandstones. Geophysical Research Letters45(20), 11, 068-11, 073.
    [Google Scholar]
  19. Nasralla, R. A. and Nasr-El-Din, H. A.
    [2012] Double-Layer Expansion: Is It A Primary Mechanism of Improved Oil Recovery by Low-Salinity Waterflooding?SPE Improved Oil Recovery Symposium. Society of Petroleum Engineers, Tulsa, Oklahoma, USA.
    [Google Scholar]
  20. Revil, A., Pezard, P. A. and Glover, P. W. J.
    [1999] Streaming potential in porous media: 1. Theory of the zeta potential. Journal of Geophysical Research: Solid Earth104(B9), 20021–20031.
    [Google Scholar]
  21. Roy, S. B. and Dzombak, D. A.
    [1996] Colloid release and transport processes in natural and model porous media. Colloids and Surfaces A: Physicochemical and Engineering Aspects107, 245–262.
    [Google Scholar]
  22. Vinogradov, J., Jaafar, M. Z. and Jackson, M. D.
    [2010] Measurement of streaming potential coupling coefficient in sandstones saturated with natural and artificial brines at high salinity. Journal of Geophysical Research115(B12).
    [Google Scholar]
  23. Vinogradov, J., Jackson, M. D. and Chamerois, M.
    [2018] Zeta potential in sandpacks: effect of temperature, electrolyte pH, ionic strength and divalent cations. Colloids and Surfaces A: Physicochemical and Engineering Aspects.
    [Google Scholar]
  24. Walker, E. and Glover, P. W. J.
    [2017] Measurements of the Relationship Between Microstructure, pH, and the Streaming and Zeta Potentials of Sandstones. Transport in Porous Media121(1), 183–206.
    [Google Scholar]
  25. You, Z., Badalyan, A., Yang, Y., Bedrikovetsky, P. and Hand, M.
    [2019] Fines migration in geothermal reservoirs: Laboratory and mathematical modelling. Geothermics77, 344–367.
    [Google Scholar]
http://instance.metastore.ingenta.com/content/papers/10.3997/2214-4609.201900072
Loading
/content/papers/10.3997/2214-4609.201900072
Loading

Data & Media loading...

This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error